ولتاژ کاری:9 تا 40 ولت DC
محدوده دمای عملکرد:-10 تا 50 درجه سلسیوس
Accuracy:< ±2%
Operating temperature:-5-+60 °C
Measuring ranges: ±500 Pa
Accuracy:10 Pa
Accuracy MM±50: ±1 Pa
Accuracy MM100: ±1 Pa
Measuring ranges:0-10000 Pa
Accuracy:10 Pa
محدوده اندازه گیری PH از 0 تا 14
رنج اندازه گیری ORP از -1999 mv تا +1999mv
سختی سنج TDS از 0~19.99~199.9~1999ppm
شوری SALT از 0~42.0ppt(آب دریا)
measure pH/EC/tds/salt/temp/DO
Nuisance-free Technology
photoelectric smoke sensor
Smoke alarm Red LED
Service alarm:
Red LED on detector
Yellow LED on control unit
Smoke alarm Red LED
Service alarm:
Red LED on detector
Yellow LED on control unit
Smoke alarm Red LED
Service alarm:
Red LED on detector
Yellow LED on control unit
Detection gas:CO
Measurement Range:0~1000 ppm
max pressure:100psi
bleed flow rate:3-7lpm
Flow Meter Accuracy:
+/- 10% of indicated value or 0.5 lpm
Oxygen Concentration 0% to 100%
oxygen Resolution 0.1% oxygen
Oxygen Concentration 0% to 100%
oxygen Resolution 0.1% oxygen
Primary Outlet Flow Range 15-120 lpm
Auxillary Outlet Flow Range 2-100 lpm
High flow range of 2-120 LPM
Low flow range of 3-30 LPM
Model R219P99-400: Flow Range 0-3 LPM
Model R219P79-400: Flow Range 0-15 LPM
Model R219P88-400: Flow Range 0-30
LPM R219P87-400: Flow Range 0-70 LPM
Model R219P88: Flow Range 0-30 LPM
Model R219P87: Flow Range 0-70 LPM
Model R219P86: Flow Range 0-120LPM
Flow Meter RP34P03-004
Flow Meter RP34P03-002
Flow Meter RP34P03-005
Flow Meter RP34P03-006
Max Pressure:100 psi
Application:Fits poles up to 1.5” diameter
Max Pressure:100 psi
Application:Fits poles up to 1.5” diameter
Oxygen Concentration:21% to 100%
Internal Filter:45 - 90 Micron Particulate
Oxygen Concentration 0% to 100%
oxygen Resolution 0.1% oxygen
Fast response, reliable and accurate measurements.
Large LCD display 21 x 18 mm for reading convenient.
Impact resistant ABS case by waterproof designed IP 57 rated.
Air velocity range: 0.4~30ms
Temp. range: -15.0°C~50.0°C
RH% range: 5.0~95.0%RH
* 3 phase/4 wire, 3 phase/3 wire, 1 phase/2 wire, 1 phase/3 wire
* True rms measurement for ACA, ACV.
* True power : W, KW, MW.
* VA, KVA, MVA, VAR, KVAR, MVAR.
* PF (power factor), phase angle.
ULTRASONIC TRANSMITTER/GENERATOR
Model: GS-400
* Ultrasonic transmitter for Gas Leakage Detector GS-5800
* 1 to 2 mV/V, exciting DC 4V to 12V.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
Grounding resistance:40/400/4000Ω
Insulation Test Voltages: 250V/500V/1000V
Insulation Resistance Range: 0.05M~1GΩ
Short Circuit Current: <2mA
Low Resistance Range 2Ω/20Ω/220Ω
* Laser beam for Photo tachometer, long measuring distance.
* LCD display, RS-232 interface.
* Patented.
160x120 resolution image w
temperature range:-20 to 350 C
D:S of 252:1
* Wood and concrete moisture measurement.
* Wood material : 6 % to 40 % moisture content.
* Concrete material : 0 % to 100 % moisture content.
* Red LED bar graph indicator with LCD display,
* Frequency & time weighting meet IEC 61672 class 1.
* 30 to 130 dB, 3 ranges, Max. hold, Data hold.
* A/C frequency weighting, F/S time weighting.
* AC output, Internal 94 dB calibration.
Acceleration: 0.1~199.9m/s2
Velocity: 0.1~199.99mm/s
Displacement:1~1999μm
Acceleration: 0.1~199.9m/s2
Velocity: 0.1~199.99mm/s
Displacement:1~1999μm
Acceleration: 0.1~199.9m/s2
Velocity: 0.01~19.99cm/s
Displacement: 0.001~1.999mm
Measuring range:
0 to 10 000 ppm
0 to 1 %vol
0 to 20 %LEL
AC Currrent:4 to 400A
DC Current:40A/400A
AC/DC Voltage:600
Resistance up to 40M ohm
Capacitance up to100uF
Frequency up to 10Hz~1MHz
Wide measuring range from 0.01A to 1000A
Measures AC and DC Voltage up to 600 volts
Measures resistance from 0.01Ὠ up to 40MὨ
Air velocity range: 30~0.0 m/s
Temp. range: -20~60°c
range: 200.0 W/m2 ,2000 W/m2
accuracy:±0.7dB
Range: 100ppm HCN limit of performance warranty
Sensitivity: 80 to 140 nA/ppm in 30ppm HCN
Response time t90: < 120 (s) from zero to 30ppm HCN
Resolution: < 0.05 RMS noise (ppm equivalent)
measuring signal: 0-100V, 100V version , 0-33V, 33V Version
Power supply input positive and negative:3.5-30V
Bandwidth : 200 MHz
Sample rate : 2GS/s
Max. Input voltage:400 V (peak)
CO Measuring range 0...300 ppm
pressure measurement:0-360bar
High-accuracy pressure measurement 0.15 % RSS
pressure measurement:0-17bar
High-accuracy pressure measurement 0.15 % RSS
High precision mA leakage measurement.
ACA 40 mA x 0.01 mA
ACA 400 mA x 0.1 mA
ACA 40 A, 120 A.
Measurement range CO2: 0 to 2% vol
Frequency Output:10 MHz
Sample rate : 125MS/s
با 8 ورودی یونیورسال
با 6 خروجی سوئیچینگ و 4 خروجی از 0 تا 10 ولت
QBM66 different models:
QBM66.201,QBM66.202,QBM66.203,QBM66.204
for liquids in piping DN 10…25
Flow range: 1.8 …150 l/min
for liquids in piping DN 10…25
Flow range: 1.8 …150 l/min
for liquids in piping DN 10…25
Flow range: 1.8 …150 l/min
for liquids in piping DN 10…25
Flow range: 1.8 …150 l/min
handle the following controlled variables:
Temperature, relative/absolute humidity
pressure/differential pressure, airflow
indoor air quality and enthalpy
RLU2 different models:
RLU202,RLU220,RLU222,RLU232,RLU236
Can be used as a heating circuit controller
and / or primary controller boiler controller
or DHW controller
41programmed plant types
RMU different models: RMU710B,RMU720B,RMU730B
pressure measurement:0-360bar
High-accuracy pressure measurement 0.15 % RSS
pressure measurement:0-360bar
pressure measurement:0-360bar
pressure measurement:0-17bar
pressure measurement:0-360bar
High-accuracy pressure measurement 0.15 % RSS
pressure measurement:0-360bar
High-accuracy pressure measurement 0.15 % RSS