Transmitters

Transmitters

 

View as Grid List
Sort by
Display per page

Carbon Monoxide alarm Detector LM-201A

CO range: 25PPM to 550PPM
alarm for more than 85 db
$ 23.48

Display and pressure controller HC12

در رنج های : 0 تا 250 پاسکال،رنج 500± پاسکال،رنج 2000± پاسکال ، رنج 50± پاسکال
$ 147.83

carbon monoxide alarm GS811

CO range:20PPM to 999PPM
alarm for more than 85db
$ 33.04

HT83 air pressure difference transmitter

50% Pascal suffering
Range 0 to 250 Pascal
500% Pascal suffering
Suffering 2000 ± Pascal
$ 130.43

PS Series Mechanical differential pressure switch

Accuracy of switching point for low limit type:
±5 Pa
(PS1500: ±20 Pa, PS4500: ±100 Pa)
Accuracy of switching point for high limit type:
PS200: ±20 Pa, PS300 & PS500: ±30 Pa
PS600 & PS1500: ±50 Pa, PS4500: ±200 Pa
$ 30.86

Kimo CO COST

CO measurment from 0 to 500 ppm
$

CO 112

measuring range co2: from 0 to 5000 ppm
$

COT-212

CO2 range: From 0 to 20000 ppm
Temperature range: 0 to +50°C
$

Kimo CO-110

CO measurement range : 0 to 500ppm
$

kimo COT-210 transmitter

CO measurement range : 0 to 500ppm
$

K85

Measurement range:0-2000ppm
Product number:085-0-0001
$

Model A2G-55

Measuring range:0-5,000 Pa
Output signal: 0-10V or 4-20 mA
$

DPT-R8 differential pressure transmitters

Accuracy for models 250 and 2500:
Pressure < 125 Pa = 1 % + ±2 Pa
Pressure > 125 Pa = 1 % + ±1 Pa
Accuracy for model 7000:
Pressure< 125 Pa = 1.5 % + ±2 Pa
Pressure > 125 Pa = 1.5 % + ±1 Pa
$

DPT-Flow flow transmitter

Output signals for pressure and air flow
0-10VDC
4-20mA
$

PTL Pressure transmitters

Accuracy:±%1,0 Output:0-10 V or 4–20 mA
$

DPTL Differential pressure transmitter

Accuracy (from FS):±%1
Output:0 to 10 V or 4 to 20 mA
$

HM110 HYGROMETRY TRANSMITTER

(IP 65 (remote and duct mount models) and IP 20 (ambient model
Ambient mode rangel: from 0 to 95 %RH
Duct mount model range: from 0 to 95 %RH
Terminal block model range: from 0 to 95 %RH
$

KIMO CTV-210

Hotwire range: from 0 to 30 m/s
Omnidirectional probe range: from 0 to 5 m/s
temperature range:From 0 to +50°C
IP 65
$

KIMO CTV-310

Measuring : from 0-1 m/s to 0-30 m/s
temperature: 0 to +50°C.
$

TR-TMK1A4TEMP. (Type K) TRANSMITTER

* Range : 0 to 500 oC. * Output : 4 to 20 mA, DC. * Power : 90-260 ACV.
$

DPT-2W differential pressure transmitter

Accuracy (from FS):±%1.5
(Long term stability:≤ ± 8 Pa(for model 2500
$

DPT-MOD differential pressure transmitter

Communication:RS-485 Modbus
Measure and monitor:
in-duct volume flow
velocity or differential pressure
$

DPT-Flow-Batt transmitter

Accuracy (from FS):±%1.5
$

DPI Electronic differential pressure switch

Output signal:0−10 V
Accuracy:± %1.5
Long term stability:±1 Pa
$

PTE-OI Outside air temperature/illuminance sensor

Measuring range:0-1000 lx
Accuracy:
NTC10k ± 0.25 °C
NTC20k ± 0.25 °C
Pt1000 ± 0.3°C
Ni1000 ± 0.4 °C
Illuminance sensor ± 20 % @ 100 lx
$

model A-10 pressure transmitter

Measuring range:0-1,000 bar
Non-linearity:%0.25 or %0.5
Output 4-20 mA, DC 0 -10 V
$ 82.61

model C-2 pressure transmitter

Measuring range:0-60bar
$

model E-10 pressure transmitter

Pressure Measuring range:0-1000bar
accuracy of ≤ %0.5
$

model E-11 pressure transmitter

Pressure Measuring range:0-1000bar
accuracy of ≤ %0.5
$

model N-10 pressure transmitter

Pressure Measuring range:0-5000psi
Non-linearity 0.2 % of span
$

model N-11 pressure transmitter

Pressure Measuring range:0-5000psi
Non-linearity 0.2 % of span
$

model O-10 pressure transmitter

Measuring range:0-600 bar
Non-linearity: %0.5
$

model S-10 pressure transmitter

Pressure Measuring range:0-1000bar
Non-linearity 0.2 % of span
$

model S-11 pressure transmitter

Measuring range:50 InWC to 8,000 psi
Output 4-20 mA, DC 0 -10 V
$

model SA-11 pressure transmitter

Measuring range:0-25bar
$

KIMO TH-110 transmitter

From 5 to 95 %RH
Ambient model: from 0 to +50°C
Duct mount model and remote: from -20 to +80°C
$

TR-DOT1A4DISSOLVED OXYGEN TRANSMITTER

* Range : 0 to 20 mg/L. * Output : 4 to 20 mA, DC. * Power : 90-260 ACV.
$

TEMP. (Pt 100 ohm) TRANSMITTER

* Range : -100 to 400 oC. * Output : 4 to 20 mA, DC. * Power : 90-260 ACV.
$

AVT air velocity and temperature transmitter

Accuracy for range 0-20 m/s
<1m/s+5%
output voltage:0–10 V
output current:4–20 mA
$

DPS 200 differential-pressure-transmitter

differential pressure range 6-1000 mbar
Accuracy ≤ ± 1%
$

Model IS-3 Pressure transmitter

Measuring range from 0 to 6,000 bar
$

Kimo TH-210 Transmitter

From 5 to 95 %RH
Ambient model: from 0 to +50°C
PC remote probe: from -20 to +120°C
Inox remote probe: from -40 to +180°C
$

DPT-Ctrl

voltage output:0-10V
current output:4-20mA
$

Model MH-3 pressure transmitter

Measuring range from 0 to 6,00 bar
$

Kimo TH-300 Transmitter

Ranges :from 0-100%RH
and -40 to +180°C
$

TM-110 temperature Transmitter

Duct mount model range: from -20 to +80°C
Ambient model range: from 0 to +50°C
Terminal block model range: from -100 to +400°C.
with housing
$

TR-PS2W-xxBAR2 WIRES PRESSURE TRANSMITTER

* 2 wires, both for signal and power supply. * Precision ceramic type pressure sensor. * External zero and span adjustment.
$

CDT2000

accurancy
CO2: ±40 ppm + 2 % of reading
DC model: 75 ppm or 10 % of reading
Temperature: <0.5 °C
$

CDT2000 Duct

accurancy
CO2: ±40 ppm + 2 % of reading
DC model: 75 ppm or 10 % of reading
Temperature: <0.5 °C
$

DPT-IO-MOD

Accuracy
(model 2500):
Pressure < 125 Pa = 1 % + ±2 Pa
Pressure > 125 Pa = 1 % + ±1 Pa
Accuracy
(model 7000):
Pressure < 125 Pa = 1.5 % + ±2 Pa
Pressure > 125 Pa = 1.5 % + ±1 Pa
$

RHT Humidity transmitter

output voltage:0–10 V
output current :4–20 mA
Temperature accurary: <0.5 °C
Relative humidity accurary: ±2-3 % rH at 0-50 °C
$

RHT Duct Humidity transmitter

output voltage:0–10 V
Temperature accurary: <0.5 °C
Relative humidity: ±2-3 % rH at 0-50 °C
and 10-90 % rH
$

Pressure sensor Model HP-2

Measuring ranges: 0 to 15,000 bar
%Accuracy: 0.5 % or 0.25
$

TR-SLT1A4SOUND TRANSMITTER

* Range : 30 to 130 dB, 3 ranges. * Output : 4 to 20 mA, DC. * Power : 90-260 ACV.
$

TST Thermostat

IP65
Temperature:
Min.: -100 °C (-148 °F)
Max.: 400 °C (752 °F)
$

Carbon Dioxide Gas Transmitter Model HT83

Range 0 to 10,000ppm
Output voltage or current
Medbass Protocol
$ 173.91

Peripheral Temperature and Humidity Transmitter Model HT83

Temperature measurement range -20-70 ° C
Humidity measurement range: 10-95%
$ 39.13

Model R-1 Pressure transmitter

Measuring range from 0 to 1,000 bar
$

GCO1 carbon monoxide and explosive gas alarm

with electrochemical CO sensor
with metal oxide explosive gas sensor
alarm at the following levels:
400 PPM CO between 4 and 15 minutes
150 PPM CO between 10 and 50 minutes
70 PPM CO between 60 and 240 minutes
$

TR-VBT1A4VIBRATION TRANSMITTER

* Range : 200 m/s2, 200 mm/s. * Output : 4 to 20 mA, DC. * Power : 90-260 ACV.
$

DPS 300 pressure transmitter

differential pressure:0 to 1000 mbar
accuracy: 0.5%
$

CO250 detector

electrochemical CO sensor
Audio Alarm: 85dB at 10 feet
$

Model MG-1 Pressure sensor

Measuring ranges from 0 to 400 bar
Output signals
4-20mA and 0-10VDC
$

TR-LXT1A4LIGHT TRANSMITTER

* Range : 2,000/20,000/50,000 Lux. * Output : 4 to 20 mA, DC. * Power : 90-260 ACV.
$

Model A2G-52

Measuring range:-250 to +2,500 Pa
and -250 to +7500 Pa
Output signal:Modbus
$

Model P-31 Pressure sensor

Accuracy: %0.1
$

CMT Carbon monoxide transmitter

Measuring CO range:0-300ppm
Measuring element:Electro-chemical
$

Model P-30 Pressure sensor

Accuracy: %0.1
$